Do you know the control principle of three pressure relays in water-cooled chillers? The relays used in water-cooled chillers are high-voltage relays, low-voltage relays, and hydraulic relays.
Yupdeng Microwave Sensor LED Bulb
Product categories of microwave sensor led bulb, we are specialized manufacturers from China, motioon sensor led bulb suppliers/factory, wholesale high-quality products of motion sensor lamp R & D and manufacturing, we have the perfect after-sales service and technical support. Look forward to your cooperation!
Company
Founded in 2004, Jiangmen YIDENG Lighting Technology CO., LTD has evolved into a global company that designs, engineers and manufactures innovative and decorative lighting solutions with a new sustainable LED collection for residential, retail, hospitality, museum, industrial and commercial applications.
We have developed an extensive line of award-winning LED luminaires including patented products and revolutionary LED fixtures. Technical innovation is central to what people have come to expect from YIDENG Lighting brand.
YIDENG Lighting has become a recognizable brand name as the microwave sensor leader with a stellar reputation for excellence in technology and design: a reliable name that you can trust for superior quality, innovative technology and superlatives service.
1. High-voltage relay It is also called the exhaust pressure controller, which directly controls the high-pressure pressure of the chiller refrigeration system. When the condenser of the water-cooled chiller is insufficient, the water temperature is too high, the water is cut off, or the high pressure exceeds the maximum pressure set on the exhaust pressure controller, the controller takes off and disconnects the circuit of the contactor to make the compressor Shutdown protection system. Note: The set pressure of the high-voltage relay is related to the type of refrigerant and the performance of the compressor. It is generally about 0.1 to 0.2 MPa higher than the highest exhaust pressure.
Second, the low voltage relay is also called the suction pressure controller. If the water-cooled chiller refrigeration system is clogged, the heat load is too low, the refrigerant is missing, the valve is forgotten, or the low pressure is too low, the controller will trip and disconnect the contactor circuit. At this time, the compressor stops. Ensure that it does not operate under too low pressure and improve the economics of system operation. Note: The setting values ​​of low-voltage relays are generally common, generally around -0.1 to -0.55MPa.
Third, the oil pressure relay
We can also call it the differential pressure controller, that is, the pressure difference between the suction pressure and the oil pressure, which is set according to the performance of the compressor. For example, for a chiller without an unloading device, the oil pressure is generally 0.1 MPa higher than the suction pressure, and for a chiller with an unloading device, the oil pressure is generally 0.15 to 0.3 MPa higher than the suction pressure. The portion higher than the suction pressure is the difference, that is, the setting value of the differential pressure controller.