Soderberg Electrode Paste is also called Anode Paste, Self-baking Electrodes Paste or Electrode Carbon Paste. It is used as conductor in submerged arc furnace under self-baking process while manufacturing different types of Ferro Alloys and Calcium Carbides.
Carbon Paste Electrode by CarboGraphite has high density and good electrical conductivity, and low ash content. Our Carbon Paste Electrodes are saying its good performance on customers' working sites.
Carbon Electrode Paste Uses, Paste Electrode Application
It is used as a conductor in submerged Arc Furnace under Self Baking Process commonly known as Soderberg Electrode and is widely used in Ferro Alloys, Carbide Industry & Metal Cleaning Process.
Carbon Electrode paste is used for forming continuous self-baking electrodes (It is also called Soderberg Electrode Paste) in electrical thermal furnaces for the production of a various types of ferroalloys, carbide industry & metal cleaning process.
CarboGraphite started its business as a producer of electrode paste since 1992, it has grow into a professional
manufacturer of carbon electrodes products, with main prodcuts Carbon Electrode Paste and graphite electrodes,
Learn know-how with over 20 years' expertise, CarboGraphite has made itself as a reputed name home and aboard.
Our carbon electrode paste capacity reach 20,000MT/year, and capable to produce 60,000MT of quality graphite electrodes annually.
Our carbon graphite electrodes are made to last, this make us reputed member of CCIA (Chinese Carbon Industry) Assosiation.
we help our agents and disctributors in Iran, Europe to thrive their business. In the years to come, we are looking for more partners
and to share more for our customers, our agents and distributors.
Electrode Paste Electrode Paste,Ferro Nickel Electrode Paste,Ferro Chromium Electrode Paste,Ferro Silicon Electrode Paste Carbographite Industrial PTE.LTD , https://www.carbographite.com
To enable the thermal expansion valve to perform the automatic adjustment function under one operating condition, it must be adjusted when the cooling system is commissioned, so as to ensure that the thermal expansion valve can perform automatic adjustment correctly during system operation.
Adjustment of the thermal expansion valve is achieved by adjusting the rod. Rotation or twisting of the adjusting rod is essentially the compression or relaxation of the spring, that is, adjusting the size of the superheat of the static assembly of the thermal expansion valve to meet the needs of refrigeration conditions. General rotation into the forward, counter-rotation back. When you want to adjust the evaporation pressure, you can remove the cap and use a wrench to rotate the adjustment rod so that the compression of the spring increases, forcing the diaphragm to move upward and closing the small valve, and the evaporation pressure will gradually decrease. Similarly, the anti-rotation lever will open a large valve and increase the evaporation pressure.
When adjusting the thermal expansion valve, a low pressure meter should be installed on the compressor suction valve to observe the change of the evaporation pressure. The normal evaporating pressure is from the frost or condensation knot to the suction duct (white frost in medium and low temperature equipment; condensation in air conditioning equipment). If the frost or condensation is connected to the suction valve or even half of the compressor, the valve is too large and it should be turned down. If the frost or condensation only reaches the evaporator outlet or the outlet does not, the valve If you are too young, you should make some adjustments.
The adjustment of the thermal expansion valve can generally be carried out in two steps. The beginning is a coarse adjustment, that is, it can be rotated about once per adjustment. When the equipment is close to its operating conditions, fine-tune it by rotating 1/4 to 1/2 turn each time. After each adjustment, the system shall be operated for a few minutes or ten minutes, and the change of the low-pressure meter shall be observed, and the next adjustment shall be decided. At the end of the expansion valve commissioning, the cap should be screwed on and tightened with a spanner to prevent refrigerant leakage.
Adjusting the thermal expansion valve is a meticulous task. Avoid urgency during the adjustment process. The adjusted thermal expansion valve must not be adjusted for other reasons unless the chiller changes operating conditions. In general, the unit of the complete machine, thermal expansion valve has been adjusted before leaving the factory, the unit should not be adjusted in the field when debugging.
2. Inspection operation of thermal expansion valve
The common failures of thermal expansion valves are plugging, leakage of working fluids in the temperature-sensing package, and so on.
(1) Valve hole plugging The valve hole is blocked by ice blocking and oil blocking. If the refrigeration system contains water, it will dissolve in the refrigerant, and the amount of dissolution is related to the temperature of the refrigerant. When the temperature is high, the amount of dissolution is large, and when the temperature is low, the amount of dissolution is small. When the refrigerant liquid with a condensing temperature of about 30t flows into the orifice of the expansion valve, it immediately cools down to the saturation temperature (evaporation temperature) under the evaporation pressure, and part of the water is precipitated. If the evaporation temperature is below 0°C attached to the hole portion of the valve, It forms ice, and when the ice builds up, the valve hole is blocked.
Refrigerator oil and refrigerant also dissolve each other, and the amount of dissolved oil is also related to the temperature. The high temperature has a large amount of dissolved, and the low temperature has a small amount of dissolved. When the liquid decompresses the orifice of the expansion valve and its temperature drops rapidly, part of the refrigerating machine oil is separated and sticks around the valve hole. When the evaporation temperature is lower than the freezing point of the refrigerating machine oil, the refrigerating machine oil will condense into a paste. As the oil gradually increases, the valve hole is blocked. Because the lower the evaporation temperature, the easier the water and oil are separated, so the ice blocking and oil blocking can easily occur in the low-temperature refrigeration equipment with a low evaporation temperature.
1 Valve hole ice blocking or oil blocking judgment. When the refrigeration unit starts operating normally, after a period of time, the suction pressure rapidly drops to negative pressure (vacuum), the temperature of the warehouse (chamber) rises, and the frost layer melts (first the frost layer of the suction pipe melts), and the side ear cannot hear it. The sound of flow to the expansion valve. At this time, it can be basically judged that the valve hole is blocked by ice or oil. To further confirm that the valve hole is blocked, an alcohol lamp can be used to heat the expansion valve body (without shutting down), and after heating for a minute or two, if you hear the sound of a "hum...", then you can hear a "click" sound. The inspiratory pressure also rises, and the outlet of the expansion valve begins to knot again. The valve hole is indeed blocked by ice or blocked by oil.
2 troubleshooting methods. Replace the desiccant in the desiccant filter. When the moisture content is high, you can use reagent-grade anhydrous calcium chloride. After replacing the pepper for a couple of days, replace the silicone. If there is no dry filter in the system, a dry filter can be connected temporarily.
(2) Expansion filter inlet filter The filter mesh that blocks the expansion valve is overly contaminated with contaminants and does not cause the valve hole to become blocked. When there are many impurities in the filter, the mesh is not very open or even completely blocked. The phenomenon is also the vacuum suction month, the library (room) temperature does not drop, and half or the entire expansion valve end of the song listens to the expansion valve has a weak "å±, å±" intermittent sound, indicating that the filter is not smooth All blocked. When tapping on the valve's inlet connector with a spanner handle, if you hear "the sound is louder than the original sound, then it is confirmed that most of the screen's mesh is blocked and the seriousness of the plug is not heard by the refrigerant gas inside the valve." Valve Body: It is not effective to use a wrench handle to knock the mouthpiece joint, but the filter mesh is completely blocked.
The obvious difference between the plugging of the filter and the blockage of the valve hole is that the blockage of the valve hole occurs when the pump is operating normally within the time. If the unit starts to suck or pull the vacuum, the filter plugs. The phenomenon that occurs when the refrigerant is insufficient and the phenomenon when the filter is clogged should be distinguished in the judgment of the continent. When the refrigeration unit is running, if you hear the expansion valve has a "click" sound, the sound is louder, the suction pressure is also lower, the suction pressure table fluctuations, the library (room) temperature is not low enough, part of the evaporation tube does not knot Hoar frost, lack of refrigerant, do not mistaken for expansion valve failure. The method of removing the plugged filter is to remove the filter and clean it with gasoline.
(3) Leakage of the working medium in the induction mechanism When the tear in the induction mechanism leaks, the induced pressure of the temperature sensing pack disappears, causing the valve to close. The tear chiller unit started to pull vacuum, and the temperature in the library did not fall. The expansion valve did not have any sound of airflow. Remove the expansion valve, remove the strainer interface, and use the mouth to inhale the outlet fitting of the expansion valve. If it fails to breathe, and can use the lips to hang it, it means that the valve hole does not pass through. It is true that the valve will not open and the same type of expansion valve should be replaced.
Expansion valve adjustment and repair method Shanghai shut-off valve manufacturer
1. Thermostatic expansion valve adjustment techniques and taboos