How to choose drainage pump

Drainage pumps used in the building have submersible sewage pumps, submerged non-clogging sewage pumps, vertical sewage pumps and horizontal sewage pumps. As the site of the building is generally small, the displacement is not large, the drainage pump can be preferentially used submersible sewage pump and submerged non-clogging sewage pump, which is generally used in the important places of liquid sewage pump; vertical sewage pump and horizontal sewage pump Requires setting base isolation, self-filling water absorption, and occupy a certain site, it is less used in buildings. Drainage pump flow rate should be selected according to life drainage design second flow; when the displacement adjustment, according to the life drainage maximum hour flow selected. Fire elevator pool drain pump flow rate of not less than 10L / s. Drainage pump lift by lifting height, pipe loss calculation is determined, then add a certain free head. Free head should adopt 0.02 ~ 0.03MPa. Drainage pump suction pipe and outlet pipe flow rate should not be less than 0.7m / s, and should not be greater than 2.0m / s. Public buildings should be used for each living drainage cistern as a unit to set up a spare pump, usually should be run interactively. Basement, equipment room, garage flushing the ground drainage, if there are two or more than two drainage pump equipment pump. When the catchment can not set the accident drain, the pump should have uninterrupted power supply; when you can close the drainage pipe, it may not provide uninterrupted power supply, but should set the alarm device. When upgrading sewage and wastewater with larger impurities, the outlet pipes of the submersible sewage pump in different sumps should not be merged and discharged. When upgrading the general wastewater, the discharge pipes of submersible sewage pumps of different sumps may be merged and discharged according to the actual situation . When two or more pumps share one outlet pipe, a valve and a check valve shall be installed on each outlet pipe of the pump. A single pump drainage may occur when the backflow should be set check valve. Do not allow the pressure drain and the building gravity drainage pipe merged discharge. When the submersible sewage pump to enhance large debris, the submersible sewage pump should be equipped with a comminution device; when upgrading with more fibrous waste water, should adopt a large submersible sewage pump. When the submersible sewage pump motor power is greater than or equal to 7.5kW or outlet diameter greater than or equal to DN100, the pump can be fixed auto-coupling device; when the submersible sewage pump motor power is less than 7.5kW or outlet diameter less than DN100, the hose can be set Mobile installation. Sewage collection pond submersible sewage pump drainage, water pumps should be set fixed auto-coupling device to facilitate pump maintenance. Drainage pump should be able to automatically start and stop and on-site manual start and stop. Multiple pumps can be alternately operated in parallel, but also can be put into operation in stages.

Automatic Led Light Sensor

Automatic Motion Sensor Led Lamp,Automatic Led Light Sensor,Automatic Motion Sensor Led Light,Led Automatic Lights

Foshan Nai An Lighting Electric Co.,ltd , https://www.fsnaipsled.com