Rainwater tank pump instruction manual

Rainwater Tank Pump Instructions for use Jiading Rain Water Tank Pump 2000/11, Note for the user manual Read instructions carefully and pay close attention to the points shown here. Know the correct usage of water tank pump through instruction manual. For reasons of safety , Children under 16 years of age and those not familiar with the instructions can not use the rain water tank pump.Please put this instruction manual in a safe place.Please strictly comply with the manufacturer's instruction manual, which is the correct use of the pump .2, Correct use of Jiading Nana rainwater tank pump is designed for pumping water and designed for special pumps, especially for pumping rainwater collector or water tank in. This pump can be completely immersed in The water can be immersed in water (maximum immersion depth is 7 m) and can not be used to pump salt, mud, corrosive, flammable and explosive liquids (eg gasoline , Kerosene and thinner), oil, heating oil or food, etc. The temperature of the rainwater pumped shall not exceed 35 ℃ .3, Functional components (Figure A) 26.5 mm (3/4 inch) pipe nipple Telescopic pipe Stop valve Handle Tip Power Cable Cable Clamp Clamp Telescopic Pipe Threaded Connector 4. Preparation before use (Picture AD) 4.1 Installation 1. Screw the Telescopic pipe connector with internal thread onto the 3/4 inch thread connector ① on the pump , As shown in Figure B. 2. Loosen the threaded collar ⑧ of the telescopic tube and adjust its height by extending or retracting the telescopic tube to reach the height of the rainwater collection container or rainwater tank. As shown in Figure B (away from the pump) .3, the power cable is fixed to the cable clamp ⑦ ⑦ (Figure D) .4, if you want to draw water from the deeper pool (maximum depth of 7 meters) Attach a rope to the carrying handle ④ 5. Place the pump in the rain trap as shown in Figure C and stop valve ③ over the edge of the rain trap or storm water tank so that when the pump is running Stopcock ③ can be used as a faucet.4.2 Use of Rain Pumps Applications: Rain Water Tank Pumps are designed to deliver rainwater from a rainwater collector or water tank, for example by delivering rainwater from a Jiading Nana rainwater tank . The use of telescopic tube stop valve ③, the pump is the use of guns, Jiading Na drip drip irrigation system (dripper interface) Jia Ideal hose for watering hoses, filling water tanks, etc. NOTE: For operation of drip irrigation system equipment, this equipment is limited by the connection of drippers such as the type shown in the table attached to the Model 2000 main unit The maximum installation of the drippers is reduced by 50% when installed as ①, ④, and ⑤ because the maximum pressure is 1.1 bar and the normal operation of the drip irrigation system nozzle can not be maintained. Important: When using a 19 mm (3/4 inch) Hose fittings, the relatively high water pressure (greater jet power) can be obtained from the irrigation equipment due to the reduced frictional loss of the hose.The recommended solution for rainwater harvesting and application system is as follows (Figure C (a) Cathay Pacific Rainwater Collection Filter (Cat. No. 3820/3821) (b) Cathay Pacific Cat Nozzle Kit (Cat. 3815) (c) Cathay Pacific Rainwater Tank (Cat. 3800/3804) ) GARDIN NAC kit cover (Cat. No. 3801/3805) (e) GARDEN NABRA water tank pump (Cat. 1466) The telescopic tube telescoping tube can be adjusted from approximately 62 to 91 centimeters so that the storm water tank pump can adapt Different depths of the rain water tank. The elbow of the telescopic pipe can be used to hang the water pump in the rain tank, which helps the water The pump avoids dirt deposited on the bottom of the rain trap. The adjustable tube is fitted with a Gardiner control valve. We recommend the Gardiner standard hose fitting. The 2015/2915 is 13 mm (1/2 inch) Cat. No. 2016/2916 are 16 mm (5/8 inch) and 19 mm (3/4 inch) and they are to be connected to the corresponding hoses. Use in a Hollow Container (Illustration F) If the Rainwater Tank Pump is used in a hollow container , Such as: emptying inflatable children's pool, the telescopic tube can be removed, replaced by Jia Dingna brand thread faucet connector specifications 26.5 mm (3/4 inch pipe thread), No. 2901/2801 hose connector 13 mm (1/2 inch), 16 mm (5/8 inch), or 19 mm (3/4 inch) for threaded hose connections to the Gardiner Basic System or the Gardiner Mass Flow System. Operation Plug the power connector of the pump into the AC outlet of 230 V. Beware! The pump will start running immediately! 6. Safety Precautions: The rain water tank pump is especially suitable for pumping rain water from the collecting container, such as: According to VDE 0100 (VDE, German Society of Electrical Engineers), the pump can only be used in swimming pools, garden ponds, fountains and devices with earth leakage protection devices with a leakage current of less than 30 mA Please consult with professional electric operator. The diameter of the power cable should not be less than the corresponding standard rubber sheath wire diameter specified in H05 RNF, the shortest cable length is 10 meters. The extension cable must meet the requirements of German DIN VDE 0620 Requirements The power plug and extension connector must have splash protection Before using the pump, first check the appearance of the pump to see if there is damage (especially wires and plugs) and found damaged pump is not allowed. Please check with our service center to check the pump.Make sure the connectors of the plugs and sockets are in a safe area that will not be flooded.Pay attention to protect the power cable ⑥ and the power plug from heat and oil and Damage to sharp objects Check the mains voltage and the parameter data on the nameplate must be consistent with the mains parameters Do not allow children under the age of 16 to operate the pump and children should stay away from the pump when connected to the water pump Check the data given in Section 9 Minimum water level. See maximum delivery height (see section 9) .7, Handling precautions Do not allow the pump to dry, otherwise excessive wear will result. When pumping, the pump should be switched off immediately (unplug the power cord) .If anyone is to enter the pool, be sure to unplug the power plug before he enters the pool.If overloaded, the integrated built-in thermal protector on the motor will The pump is switched off and the pump is restarted automatically once it has cooled down (see Note in Section 10 "Faults, causes and repairs"). The power must be cut off after the pump has been used. Do not switch off the power at the extension of the cable , But should be cut off at the outlet of the power supply. The power cable can not be used to bundle or carry the pump. The submersion or pull-out of the pump should be carried out through the telescopic tube. A rope can also be attached to the portable handle ④ for lowering, Fix the pump and clean the filter every time the dirty rain is drawn in. The rain water tank The pump body is equipped with an exhaust plug ⑩, the function of this exhaust plug is to exhaust air trapped in the pump body, ① A small amount of water will flow out from the gap between the pump body and water if there is a further drop in the pump body, which is caused by the exhaust gas instead of a fault or defect. Close or Plug, the pump can not run continuously for more than an hour. Rain water tank pump suction height drops, the remaining water height is about 15 mm .8, repair, maintenance, preservation Caution! Pump before any treatment, should be unplugged from the power Plugs! 8.1 CLEAN FILTER (Figure E) Most of the components of the Gardiner Rainwater Tank Pump are maintenance-free except for a built-in filter that protects the pump and connected equipment from contamination. Depending on the cleanliness of the rain, the filter should be checked regularly for cleaning to prevent clogging. The cleaning procedure is as follows: Open the pull tab on the suction head of the housing and loosen the double snap on the filter (Figure E) Pull down to remove the suction head . Clean the strainer under flowing water, then reinstall and lock as per the original procedure. Insert the strainer back into the pump and attach the suction head. CAUTION! The nipples on the pump housing are deadlocked and any Electrician maintenance work must be completed by Jiading take service center. Save the pump in a dry place, to avoid frost .9, Technical parameters Rated power Maximum delivery capacity Maximum pressure Maximum delivery height Maximum immersion depth Minimum working depth of the power cord Weight (not band Telescope) Maximum Water Temperature Operating Voltage / Frequency Noise Level LWA1) Noise Level LWA1) 3002,2001.111710 m Approx. 5.5 approx. 3.935230 V / 50 Hz5565wattI / hbarmmH05 RNF level cmkg ° C dB (A) (Immersion) dB 10 cm) 1) Measurement method according to EN 60355-1 10, Malfunction Possible cause Remedy Pump is running but not out of water Air can not be cleared due to blocked pressure line Open pressure line ( Such as: check valve, delivery device), may also be pressure hose New twist up the suction head with air up to 60 seconds until the pump to clear the air just fine, if necessary, turn off the pump, and then restart Start-up. Suction head and filter ⑤ Clogged. Clean the suction head and filter (see section 8.1). The water level at pump operation is below the minimum water depth for operation. Dive into the water pump (see Minimum immersion in Section 9 Depth) Pump can not be started, or

T5 4 Pin UVC Lamp

Ultraviolet Bulb,T5 4 Pin Uvc Tube,T5 4 Pin Uvc Light,T5 4 Pin Uvc Bulb

Changxing leboom lighting product CO.Ltd. , https://www.leboomuv.com